An Efficient Solution to Measuring CO2 in Natural Gas Applications

Natural gas mainly consists of methane (CH4 70–90 %). There are a number of other components (ethane, propane, butane, nitrogen, hydrogen sulfide and others) including carbon dioxide (CO2) which may be present in concentrations from several ppm up to 8%. Pipeline transmission legislation sets limits for the CO2 content of natural gas. Therefore, CO2 has to be measured and, if necessary, reduced by technical processes such as amine washers, polymeric membranes, or pressure swing absorbers (PSAs).

Measuring the CO2 content of natural gas can be accomplished by various means including gas chromatography and optical non-dispersive infrared measurement. Often a simpler and more cost-effective solution is the use of a process gas analyzer setup.

Methane, ethane, propane and other hydrocarbons in natural gas influence the CO2 measurement. This cross interference is low for methane (approx. 1:700), but larger for ethane (approx. 1:100) and higher hydrocarbons. If CO2 has to be measured in the percent range, the error from cross interferences by the background gases is negligible. Calibration can be performed with the mean background concentration of the natural gas components. Even calibration in nitrogen might be possible.

For ppm CO2 ranges, calibration with mixed background gases or a nitrogen background is not possible. Varying gas composition in natural gas would lead to varying errors in CO2 measurement, which are too high for ppm measurement ranges. To overcome the problem of varying background in natural gas, a special gas analyzer setup with a CO2 absorbing agent can be used. In an external sample handling system the sample gas stream is split and the CO2 in one stream is removed with a scrubber. This stream is flowing through the reference side. The other stream which still contains the CO2 is applied to the measurement side of the analyzer cell. With this configuration, variations in the background of natural gas will affect both sides of the analysis cell and will therefore be cancelled out. In the external sample handling system, the left vessel contains the CO2 absorbing material, whereas the right vessel is a blank vessel filled with glass beads to equalize the flow.

Click to read the Application Note by Emerson.

 

 

L?pning & Utbildning

Case Study: Turkey’s refinery chooses Rotork valve automation for Retrofit upgrade

Rotork valve actuation and two-wire digital control technology has been chosen for a major upgrade and automation programme at the Tupras Izmit refinery in Turkey.

Tupras is Turkey’s largest industrial company and leading refiner, operating four refineries of which Izmit is the largest. First opened in 1961, production at Izmit of commodities including LPG, naphtha, petrol, jet fuel, kerosene and diesel is now running at over 11 million tons a year.

More than 900 explosionproof Rotork IQ intelligent electric valve actuators will be installed in a four stage project to motorise manually operated valves on the refinery’s tank farms. Nearly 800 of the actuators will be retrofitted on existing valves whilst the balance will consist of new actuated valve packages. Many of the actuators will be factory fitted with intumescent fireproof coatings.

Click Case Study to read in detalis

Nike Jordan Super Fly 4

pH/ORP Measurement for Reverse Osmosis

Reverse osmosis (RO) is a separation process that uses pressure to force a solution through a membrane that retains the solute on one side and allows the pure solvent to pass to the other side. More formally, it is the process of forcing a solvent from a region of high solute concentration through a membrane to a region of low solute concentration by applying a pressure in excess of the osmotic pressure. To illustrate, imagine a semipermeable membrane with fresh water on one side and a concentrated aqueous solution on the other side. If normal osmosis takes place, the fresh water will cross the membrane to dilute the concentrated solution. In reverse osmosis, pressure is exerted on the side with the concentrated solution to force the water molecules across the membrane to the fresh water side.

Read full Application Note by Yokogawa

Adidas

Making Accurate Temperature Measurements with Thermocouples, Thermistors and RTD Sensors

As one of the most common physical phenomena engineers and scientists monitor, temperature measurements are vitally important to ensure proper functioning of a vast array of applications. While modern systems have simplified this process for users, understanding the theories, operation, and inherent pitfalls of temperature measurements can help improve the accuracy and reliability of your data.

This white paper explains the pros and cons of the most widely-used temperature transducers: thermocouples, resistance temperature detectors (RTDs), and thermistors. Click to download the White Paper by MC Measurement Computing

Nike Air Max 2017

Working with Self-powered and Loop-powered Sensors

Quick, suppose you need to monitor sensors with a milliamp current signal. Should you get a SNAP-AIMA, a SNAP-AIMA-i, or a SNAP-AIMA-iSRC analog input module? Or what about a SNAP-AIMA-4 or a SNAP-AIMA-32?

All of these modules provide -20 mA to +20 mA analog current input connections. So which one do you need?

Read this article in full by Opto22